Geo-Hep-SystemsPLANNING · SEASONAL HEAT STORAGE FIELD01 / THE PLANNINGPlanning and sizinga Geo-Hep-Systems seasonal heat storage fieldEnergy demand and temperature levelRequired storage durationAvailable space and site conditionsTogether, these determine the design.02 / THE INDIVIDUAL MODULEGeo-Hep-Systems seasonal heat store Approx. 29 m external length 28 m internal length CROSS SECTION 1.40 mInner diameter 1.80 mOuter diameter 17 cmAnnular gap Two shells.One seasonal heat store. Length : diameter ≈ 16 : 1 · Cross section enlarged separately 03 / THE STORAGE CAPACITYThe planned module stores heat.PER INDIVIDUAL STORAGE MODULEUp to 3.8 MWhWith full thermal stratificationat a maximum of 95 °C.Capacity as specified in the project.Thermal stratification shown schematically.04 / THE MODULAR FIELDIndividual stores are connected together.Hydraulically connectedThe number and layout dependon the individual project.Pipe routes, spacing andaccess are included in the design.Connections are schematic · Symbols do not show tank heights to scale.05 / THE WORKED EXAMPLEFrom site area to storage capacity.50 × 100 mExample site · 5,000 m²153 Seasonal heat stores153 × 3.8 MWh= 581.4 MWhMaximum storage capacity in this example17 × 9 module positions · Assumed layout, not a construction design.06 / DEVELOPMENT STATUSDesign complete. Long-term testing pending.The module dimensions have been planned.Long-term testing still needs to examine:heat losses and temperature changesover periods of up to 180 days.The storage field is designedindividually for each project.Seasonal heat store at prototype stage · Long-term results are pending.